    人血管內皮生長因子(VEGF)Elisa試劑盒說明書

    Human Vascular Endothelial cell Growth Factor (VEGF) ELISA Kit

    (48Tests)

    Store all reagents at 2-8°C Collect sample: serum or blood plasma Assay range 5.0 pg/ml -950 pg/ml


    FOR LABORATORY RESEARCH USE ONLY.


    NOT FOR THERAPEUTIC OR DIAGNOSTIC APPLICATIONS! PLEASE READ THROUGH ENTIRE PROCEDURE BEFORE BEGINNING!


    INTENDED USE

    This VEGF ELISA kit is intended Laboratory for Research use only and is not for use in diagnostic or therapeutic procedures.The Stop Solution changes the color from blue to yellow and the intensity of the color is measured at 450 nm using a spectrophotometer. In order to measure the concentration of VEGF in the sample, this VEGF ELISA Kit includes a set of calibration standards. The calibration standards are assayed at the same time as the samples and allow the operator to produce a standard curve of Optical Density versus VEGF concentration. The concentration of VEGF in the samples is then determined by comparing the O.D. of the samples to the standard curve.


    PRINCIPLE OF THE ASSAY


    The kit assay VEGF level in the sampleuse Purified antibody to coat microtiter


    plate wells, make solid-phase antibody, Samples which including standards of known concentrations and unknowns are pipetted into coated microtiter wells, after Incubating ,add Biotinylated anti-IgG,and Combined Streptavidin-HRP, become antibody – antigen - enzyme- antibody complex, after washing Compley, Add TMB substrate solution, TMB Chromogen Solution Becomes blue color At HRP enzyme-catalyzed, And at the effect of acid the color finally become yellow, The intensity of this coloured product is directly proportional to the concentration of VEGF present in the samples. measure the optical densit (OD) at 450 nm with microtiter plate reader, calculate VEGF concentration by standard curve.


    REAGENTS PROVIDED


    All reagents provided are stored at 2-8° C. Refer to the expiration date on the label.

    1. MICROTITER PLATE 48 wells
    2. Biotinylated anti-IgG 3.0 mL 1 tube

    3. STANDARD(800 pg/ml)

    0.5ml 1 tube

    4. STREPTAVIDIN-HRP

    3.0 mL

    1 tube

    5. STANDARD DILUENT

    1.5ml

    1 tube

    1. Chromogen Solution A 3.0 mL 1 vial
    2. Chromogen Solution B 3.0 mL 1 vial
    3. STOP SOLUTION 3.0 mL 1 vial


    1. WASH SOLUTION x20 20 mL 1 vial
    2. Instruction 1


    SAMPLE COLLECTION AND STORAGE

    Serum- Use a serum separator tube(SST) and allow samples to clot for 30minutes before centrifugation for 15minutes at approximay 1000 x g.Remove serum and assay immediay or aliquot and store samples at -20 °C or -80°C.


    Plasma - Collect plasma using EDTA or heparin as an anticoagulant.Centrifuge samples for 15 minutes at 1000 x g at 2-8°C within 30minutes of collection.Store samples at -20°C or -80°C.Avoid repeated freeze-thaw cycles.


    Cell culture fluid and other biological fluids - Remove particulates by centrifugation and assay immediay or aliquot and store samples at -20°C or -80°C.Avoid repeated freeze-thaw cycles.


    NOTE: Serum, plasma, and cell culture fluid samples to be used within 7 days may be stored at 2-8°C, otherwise samples must stored at -20°C(≤2months) or -80°C(≤6months) to avoid loss of bioactivity and contamination. Avoid freeze-thaw cycles .When performing the assay slowly bring samples to room temperature.


    DO NOT USE HEAT-TREATED SPECIMENS.


    MATERIALS REQUIRED BUT NOT SUPPLIED


    1. Microplate reader capable of measuring absorbance at 450 nm.


    1. Precision pipettes to deliver 2 ml to 1 ml volumes. .
    2. Adjustable 10ml -100ml pipettes for reagent preparation.
    3. 100 ml and 1 liter graduated cylinders.
    4. Calibrated adjustable precision pipettes, preferably with disposable plastic tips. (A manifold multi-channel pipette is desirable for large assays.)
    5. Absorbent paper.


    1. 37°C incubator.
    2. Distilled or deionized water.
    3. Data analysis and graphing software..
    4. Tubes to prepare standard or sample dilutions.


    PRECAUTIONS


    1. Do not substitute reagents from one kit lot to another. Standard, conjugate and microtiter plates are matched for optimal performance. Use only the reagents supplied by manufacturer.


    1. Allow kit reagents and materials to reach room temperature (20-25°C) before use. Do not use water baths to thaw samples or reagents.


    1. Do not use kit components beyond their expiration date.


    1. Use only deionized or distilled water to dilute reagents.

    5.   Do not remove microtiter plate from the storage bag until needed. Unused strips should be stored at 2-8°C in their pouch with the desiccant provided.

    1. Use fresh disposable pipette tips for each transfer to avoid contamination.


    1. Do not mix acid and sodium hypochlorite solutions.

    8.  Serum and plasma should be handled as potentially hazardous and capable of transmitting disease. Disposable gloves must be worn during the assay procedure, since no known test method can offer complete assurance that products derived from human blood will not transmit infectious agents. Therefore, all blood derivatives should be considered potentially infectious and good laboratory practices should be followed.

    1. All samples should be disposed of in a manner that will inactivate viruses.


    1. Solid Waste: Autoclave 60 min. at 121°C.

    11.  Liquid Waste: Add sodium hypochlorite to a final concentration of 1.0%. The waste should be allowed to stand for a minimum of 30 minutes to inactivate the viruses before disposal.


    1. Substrate Solution is easily contaminated. If bluish prior to use, do not use.


    1. Chromogen Solution B contains 20% acetone, keep this reagent away from sources of heat or flame.


    1. Remove all kit reagents from refrigerator and allow them to reach room


    temperature ( 20-25°C).


    REAGENT PREPARATION


    Standard -The Kit provides a stock standard800 pg/ml. Allow the standard to sit for a minimum of 5 minutes with gentle mixing prior to making dilutions.Pipette 150μL of Standard Dilution into each tube.


    (total 5 tubes) Use the 150μL of stock solution to produce a 2-fold dilution series (including 400 pg/ml,200 pg/ml,100 pg/ml,50 pg/ml , 25 pg/ml). Mix each tube thoroughly before the next transfer.


    Wash Buffer - If crystals have formed in the concentrate, warm to room temperature and mix gently until the crystals have compley dissolved. To prepare enough Wash Buffer for one plate, add 20mL Wash Buffer Concentrate into deionized or distilled water to prepare 600mL of Wash Buffer.


    ASSAY PROCEDURE


    Prepare all Standards before starting assay procedure (see Preparation Reagents). It is recommended that all Standards and Samples be added in duplicate to the Microtiter Plate.


    1.       Determine the number of microwell strips required to test the desired number of samples, Each sample, standard and blank should be assayed in duplicate.


    1. add sample: Set blank wells separay (blank comparison wells dont add


    sample and ELISA reagent, other each step operation is same). Add 50 μL of Standards or Samples to the appropriate well of the antibody pre-coated Microtiter Plate, and Gently mix. Incubate for 45 min at 37


    1. Configurate liquid: 30 times of wash solution diluted 30 times with distilled water and reserve.
    2. washing: remove Liquid, dry by swing, add washing buffer to every well, still for 30 second then remove, repeat 4 times.


    1. add Biotinylated anti-IgG: Add diluted Biotinylated anti-IgG 50ul to all


    wells, Incubate for 30 min at 37


    1. washing:  Operation with 4.


    1. add streptavidin-HRP:  Add streptavidin-HRP 50ul to all wells, Gently mix


    Incubate for 15 min at 37


    1. washingOperation with 4.


    1. color: Add Chromogen Solution A 50ul and Chromogen Solution B to each well,Incubate for 15 min at 37


    1. Stop the reaction: Add Stop Solution50μl to each well, Stop the reaction(the blue color change to yellow color Immediay).


    1. assay: take blank well as zero , measure the optical densit (OD) at 450 nm after Adding Stop Solution and within 15min.


    CALCULATION OF RESULTS

    Average the duplicate readings for each standard,control, and sample and subtract the average zero standard optical density. Construct a standard curve by plotting the mean absorbance for each standard on the y-axis against the concentration on the x-axis and draw a best fit curve through the points on the graph. This procedure will produce an adequate but less precise fit of the data. If samples have been diluted, the concentration read from the standard curve must be multiplied by the dilution factor.

    留言框

    • 產品:

    • 您的單位:

    • 您的姓名:

    • 聯系電話:

    • 常用郵箱:

    • 省份:

    • 詳細地址:

    • 補充說明:

    • 驗證碼:

      請輸入計算結果(填寫阿拉伯數字),如:三加四=7
    上海慧穎生物科技有限公司 版權所有    備案號:滬ICP備12016933號-2

    技術支持:化工儀器網    管理登陸    網站地圖

    聯系電話:
    15821734033

    微信服務號

    主站蜘蛛池模板: 亚洲va在线va天堂成人| 国产成人精品无码片区在线观看| 中文字幕在线看片成人| 五月天国产成人AV免费观看| www.成人在线| 成人免费大片免费观看网站| 国产成人a毛片在线| 日本在线观看成人小视频 | 成人午夜高潮A∨猛片| 国产成人综合色视频精品| 亚洲国产成人久久综合一| 成人在线激情网| 久久成人福利视频| 国产成人精选免费视频| 日韩欧美成人乱码一在线| 免费成人福利视频| 成人影片在线免费观看| 久久亚洲色www成人欧美| 国产成人高清视频| 成人免费公开视频| 成人欧美一区二区三区黑人| 亚洲成人黄色网| 国产成人天天5g影院| 四虎成人免费大片在线| 成人免费视频观看无遮挡| 97超碰精品成人国产| 亚洲欧美成人综合| 国产成人亚洲午夜电影| 国产成人精品无码免费看| 成人影片一区免费观看| 成人精品一区二区不卡视频| 欧美成人在线观看| 日本成人在线播放| 成人免费视频试看120秒| 成人口工漫画网站免费| 成人免费观看视频高清视频| 欧美成人全部视频| 成人片在线观看地址KK4444| 欧美a级成人淫片免费看| 成人国产在线24小时播放视频| 成人综合激情另类小说|